HEATMASTER F400 (F400 only for Extra UE Countries)
Model
HEATMASTER F400 315 T4/T8 0,25/0,03kW
Code
15304

HEATMASTER F400 315 T4/T8 0,25/0,03kW

ROOF FAN WITH FOLDING SYSTEM AND ALUMINIUM COWL F400

MANUFACTURING FEATURES:

  • Protection cowl made of anticorrosive treated aluminum easily removable for motor and impeller maintenance thanks to the integrated folding system.
  • The design of the cowl with a rounded shape is specific to minimize the risk of water ingress due to rain (including rain).
  • Equipped with a hinged system to open the motor-impeller set. This system allows easy maintenance and cleaning of the set without the need to disassemble the entire structure. The opening is possible in 2 inclinations: approximately 45º and 90º, as required by the intervention.
  • Structure in anticorrosive galvanized steel and support frame for adaptation to the roof with anti-bird protection grid.
  • High-performance, backward-curved blade (reaction) impellers designed to work without scroll. Self-cleaning system, built in galvanized steel treated with anti-corrosion.
  • Standard asynchronous squirrel cage motor with IP-55 protection and Class F insulation. Standard voltages of 230V50Hz for single phase motors, 230/400V50Hz & 400/690V 50Hz for three-phase 1 speed motors and 400V50Hz for 2 speed motors.

APPLICATIONS

Designed for deck or roof mounting, they are indicated for:

  • Smoke extraction.
  • Air renewal in all types of buildings and industries.
  • Maximum continuous working temperature: transported air 80ºC, ambient 60ºC to -25ºC in three-phase motors.

UNDER REQUEST

  • Special voltages.
  • Special contruction for moving air at 120ºC

Fan

Max flow
2590 m³/h
Weight
41.5 Kg

Motor

Power
0,25/0,03 kW
RPM Motor
1370/705
I max. 400 V
1,13/0,37
Size
71M
Weight
6 Kg
Efficiency
50/48 %
FP
0,71/0,45
HEATMASTER F400 315 T4/T8 0,25/0,03kW
Loading...
Design point
Loading...
Service point
Loading...
Alternative point

HEATMASTER F400 315 T4/T8 0,25/0,03kW

Dimensions scheme
A B C D E F G GIRANTE H ØL PALA
755 610 550 325 210 40 30 315x90 575 360 90

HEATMASTER F400 315 T4/T8 0,25/0,03kW

Electrical scheme

HEATMASTER F400 315 T4/T8 0,25/0,03kW

Model
SIL-C 315/315
Code
20801
Information
CIRCULAR SILENCER

MANUFACTURING FEATURES

• Valid for mounting in inlet and outlet according to the diameter of the corresponding pipe or adapted to the diameter of an optional flange. Consult to Casals Ventilación.
• Steel housing with thickness of 0.8mm for diameters up to 1250mm; and 1mm for higher diameters.
• Silencer flange with threaded inserts.
• Acoustic rock wool insulation of 70Kg/m3 with microperforated metal mesh that protects the fiberglass from erosion. Fire resistant insulation M0.
• Attenuation test carried out according to the ISO 7235 standard.
• Drills in accordance with Eurovent regulations.
• SIL-CN are equipped with an inner core that increases silencer attenuation.
• Maximum working temperature: 150ºC.
• Suitable for pressures up to 1000Pa

APPLICATIONS

• For attenuating the sound level of the fan.
• For coupling fans and circular pipes.

Other sizes, consult us.

Model
SIL-C 315/472
Code
20802
Information
CIRCULAR SILENCER

MANUFACTURING FEATURES

• Valid for mounting in inlet and outlet according to the diameter of the corresponding pipe or adapted to the diameter of an optional flange. Consult to Casals Ventilación.
• Steel housing with thickness of 0.8mm for diameters up to 1250mm; and 1mm for higher diameters.
• Silencer flange with threaded inserts.
• Acoustic rock wool insulation of 70Kg/m3 with microperforated metal mesh that protects the fiberglass from erosion. Fire resistant insulation M0.
• Attenuation test carried out according to the ISO 7235 standard.
• Drills in accordance with Eurovent regulations.
• SIL-CN are equipped with an inner core that increases silencer attenuation.
• Maximum working temperature: 150ºC.
• Suitable for pressures up to 1000Pa

APPLICATIONS

• For attenuating the sound level of the fan.
• For coupling fans and circular pipes.

Other sizes, consult us.

Model
SIL-C 315/ 630
Code
20803
Information
CIRCULAR SILENCER

MANUFACTURING FEATURES

• Valid for mounting in inlet and outlet according to the diameter of the corresponding pipe or adapted to the diameter of an optional flange. Consult to Casals Ventilación.
• Steel housing with thickness of 0.8mm for diameters up to 1250mm; and 1mm for higher diameters.
• Silencer flange with threaded inserts.
• Acoustic rock wool insulation of 70Kg/m3 with microperforated metal mesh that protects the fiberglass from erosion. Fire resistant insulation M0.
• Attenuation test carried out according to the ISO 7235 standard.
• Drills in accordance with Eurovent regulations.
• SIL-CN are equipped with an inner core that increases silencer attenuation.
• Maximum working temperature: 150ºC.
• Suitable for pressures up to 1000Pa

APPLICATIONS

• For attenuating the sound level of the fan.
• For coupling fans and circular pipes.

Other sizes, consult us.

Model
SIL-CN 315/315
Code
20780
Information
CIRCULAR SILENCER

MANUFACTURING FEATURES

• Valid for mounting in inlet and outlet according to the diameter of the corresponding pipe or adapted to the diameter of an optional flange. Consult to Casals Ventilación.
• Steel housing with thickness of 0.8mm for diameters up to 1250mm; and 1mm for higher diameters.
• Silencer flange with threaded inserts.
• Acoustic rock wool insulation of 70Kg/m3 with microperforated metal mesh that protects the fiberglass from erosion. Fire resistant insulation M0.
• Attenuation test carried out according to the ISO 7235 standard.
• Drills in accordance with Eurovent regulations.
• SIL-CN are equipped with an inner core that increases silencer attenuation.
• Maximum working temperature: 150ºC.
• Suitable for pressures up to 1000Pa

APPLICATIONS

• For attenuating the sound level of the fan.
• For coupling fans and circular pipes.

Other sizes, consult us.

Model
SIL-CN 315/472
Code
20781
Information
CIRCULAR SILENCER

MANUFACTURING FEATURES

• Valid for mounting in inlet and outlet according to the diameter of the corresponding pipe or adapted to the diameter of an optional flange. Consult to Casals Ventilación.
• Steel housing with thickness of 0.8mm for diameters up to 1250mm; and 1mm for higher diameters.
• Silencer flange with threaded inserts.
• Acoustic rock wool insulation of 70Kg/m3 with microperforated metal mesh that protects the fiberglass from erosion. Fire resistant insulation M0.
• Attenuation test carried out according to the ISO 7235 standard.
• Drills in accordance with Eurovent regulations.
• SIL-CN are equipped with an inner core that increases silencer attenuation.
• Maximum working temperature: 150ºC.
• Suitable for pressures up to 1000Pa

APPLICATIONS

• For attenuating the sound level of the fan.
• For coupling fans and circular pipes.

Other sizes, consult us.

Model
SIL-CN 315/ 630
Code
20782
Information
CIRCULAR SILENCER

MANUFACTURING FEATURES

• Valid for mounting in inlet and outlet according to the diameter of the corresponding pipe or adapted to the diameter of an optional flange. Consult to Casals Ventilación.
• Steel housing with thickness of 0.8mm for diameters up to 1250mm; and 1mm for higher diameters.
• Silencer flange with threaded inserts.
• Acoustic rock wool insulation of 70Kg/m3 with microperforated metal mesh that protects the fiberglass from erosion. Fire resistant insulation M0.
• Attenuation test carried out according to the ISO 7235 standard.
• Drills in accordance with Eurovent regulations.
• SIL-CN are equipped with an inner core that increases silencer attenuation.
• Maximum working temperature: 150ºC.
• Suitable for pressures up to 1000Pa

APPLICATIONS

• For attenuating the sound level of the fan.
• For coupling fans and circular pipes.

Other sizes, consult us.

Model
BAD 9
Code
20769
Information
CIRCULAR-CIRCULAR ANTI-VIBRATION FLANGE

MANUFACTURING FEATURES

• Circular-circular coupling flange through anti-vibration canvas.
• Fire resistance M0: from -50ºC to +200ºC in continuous and 400ºC/2h

Model
MFLAC 28/11-31/12
Code
20235
Information
CONECTION FLANGE

MANUFACTURING FEATURES

• For axial (inlet and outlet) and centrifugal (inlet) fans.

UNDER REQUEST

• Versions in stainless 304 and stainless 316.

Model
SWT 25 6P
Code
21680
Information
SAFETY SWITCH

MANUFACTURING FEATURES

• Safety start-stop switches according to IEC 60947-1 and IEC 60947-3.
• IP65 and always equipped an auxiliary contact.
• Useful for switching off the current before handling the fan.

*Máx. thermal current air (A)

Model
BTI 570 D=0 C=B
Code
20761
Information
INCLINED ROOF FAN SUPPORT

MANUFACTURING FEATURES

• Inclined support for roof fans , TORRETTE TRS EC, TORRETTE TRK R, and the resulting fans combining with the KIT TE and KIT TM

In the code, indicate the pitch instead of "XX"

UNDER REQUEST

• Specific inclination.

Model
CMP-HUT 300x310
Code
2076+3
Information
DEPRESSION DAMPER (HORIZONTAL or VERTICAL PLACEMENT)

Depression damper for ascending air flow in the intake. The slats block the passage of air when the fan is stopped while when the fan is running the slats move by depression allowing the passage of air. Robust U-shaped frame. The special holes in the corners allow a connection with common union systems on the market such as a duct working in plenum mode. It maintains the overpressure or depression inside a room with respect to the outside or another adjoining room.

MANUFACTURING FEATURES:

- Galvanized steel frame, U-shaped to install in a duct.

- Aluminum slats.

- Ø12 shafts in galvanized steel.

- Ø12 bronze bushings.

- Suitable for 400°/2h (not certified) and temperatures below zero.

- It can be installed directly to the fan, although the use of the frame (B CMP) is recommended.

- Suitable for speed 18 m/s and with some turbulence.

Model
KV HEASTMASTER 315
Code
20833
Information
KENTALROOF VERTICAL DISCHARGE

MANUFACTURING FEATURES

  • Accessory to convert the KENTALROOF roof fan to vertical discharge.
    • Manufactured in aluminuim
Model
BTI+ACMP 570 D=0 C=B
Code
20859
Information
BTI + ACMP MOUNTED

Suitable for installa CMP-HUT in a roof fan using a BTI (apti)

Made of galvanized steel

Model
BTI+AMC 570 D=0 C=B
Code
20865
Information
BTI + AMC MOUNTED

Suitable for installa ASIL in a roof fan using a BTI (apti)

Made of galvanized steel

Model
BTI+ACMP+AMC 570 D=0 C=B
Code
20869
Information
BTI + ACMP+AMC MOUNTED

Suitable for install both CMP-HUT and ASIL in a roof fan using a BTI (apti)

Made of galvanized steel

HEATMASTER F400 315 T4/T8 0,25/0,03kW