VORTICENT CMP 26-31
Model
VORTICENT CMP 31 T2 2.2kW
Code

VORTICENT CMP 31 T2 2.2kW

FORWARD ALLUMINIUM IMPELLER FAN, ALLUMINIUM CAST CASING

MANUFACTURING FEATURES:

• Cast aluminium housing.
• Cast aluminium impeller.
• Polyester powder finishing coat.
• Standard asynchronous squirrel-cage motor with IP-55 protection and Class F insulation. Manufactured with standard voltages: 230V 50Hz in single phase motors and 230/400V 50Hz in three phase motors.

• Available positions (to be indicated in case of order): LG270, LG0, LG45, LG90, LG135, LG180, LG315.
• The indicated codes correspond to the model in position LG270

APPLICATIONS:

Designed for inline installation, they are suitable for:
• Industrial applications, extraction or injection of air.
• Cooling of machines and parts.
• Clean and slightly dusty air transport.
• Maximum working temperature: carried air: 130ºC, environment: 60ºC for three phase motors and 50ºC fon single phase motors.



UNDER REQUEST:

• Special voltages.

Fan

Max flow
2180 m³/h
Weight
30 Kg

Motor

Power
2,2 kW
RPM Motor
2840
I max. 230 V
7,97
I max. 400 V
4,58
Size
90L
Weight
25 Kg
Efficiency
85.9 %
FP
0.83
VORTICENT CMP 31 T2 2.2kW
Loading...
Design point
Loading...
Service point
Loading...
Alternative point

VORTICENT CMP 31 T2 2.2kW

Dimensions scheme
A C D D1 D2 D3 D4 D5 D6 E F G H I J K L M P Q U V W X Y Z
320 160 193 530 518 513 668 620 568 555 428 240 190 323 140 200 175 120 160 180 10,2 18,5 122 13 M6 215 570 510 445 428 570 510

VORTICENT CMP 31 T2 2.2kW

Electrical scheme

VORTICENT CMP 31 T2 2.2kW

Model
SWT 25 3P
Code
21673
Information
SAFETY SWITCH

MANUFACTURING FEATURES

• Safety start-stop switches according to IEC 60947-1 and IEC 60947-3.
• IP65 and always equipped an auxiliary contact.
• Useful for switching off the current before handling the fan.

*Máx. thermal current air (A)

Model
MSRA 16/6
Code
20263
Information
INLET PROTECTION GUARD FOR CENTRIFUGAL FANS

MANUFACTURING FRATURES

• Inlet protection guard to avoid the entry of objects and contact with the impeller.
• Made of galvanised steel models 7,9, 10, 12 and 15. And the rest of models with polyester powder finishing coat.

Model
FLC1-F400 15/16
Code
21985
Information
ANTI-VIBRATING FLANGE 400º/2H

MANUFACTURING FEATURES

• Flexible polyurethane coupling flange with fiberglass fabric to avoid possible vibrations to the installation.
• 160 mm width and supplied with 2 fixing clamps.
• Certified according to the European standard EN 12101-3 400ºC/2h. Fire classification: M0.

Model
FJ-F450
Code
21669
Information
ANTI-VIBRATION JOINT

MANUFACTURING FEATURES

• Flexible joint to clinch the fan to the duct.
• Avoids transmission of vibrations for circular and rectangular connection.
• Dimensions: two metallic flanges of 45mm each one and a flexible flange of 60mm.
• The reel is 30,5m lenght.
• Maximum pressure: 20 mmca.
• Fire resistance M0 from -50ºC to +200ºC in continuous and 400ºC/2h.

Model
MFLAC 16/6
Code
20230
Information
CONECTION FLANGE

MANUFACTURING FEATURES

• For axial (inlet and outlet) and centrifugal (inlet) fans.

UNDER REQUEST

• Versions in stainless 304 and stainless 316.

Model
IREM INVERTER 230 10A
Code
12875
Information
FREQUENCY SPEED CONTROLLER

Designed for controlling fan motors speed in HACV applications. Ultra compact installation, simple cabling, easy parameterization and wide standard functions. Integrated control unit panel with digital dial. PID card. Certifications: CE/UL/CSA/EN/GOST/CCC. Protection Marking: IP20.

IREM/IRET INVERTER 230: Entrance 230V I, exit 230V III
IREM/IRET INVERTER 400: Entrance 400V III, exit 400V III

EMC filter incorporated for models from 47A (included)

*Lineal load rated current

**Quadratic load rated current

Model
IRET INVERTER 400 5A
Code
12879
Information
FREQUENCY SPEED CONTROLLER

Designed for controlling fan motors speed in HACV applications. Ultra compact installation, simple cabling, easy parameterization and wide standard functions. Integrated control unit panel with digital dial. PID card. Certifications: CE/UL/CSA/EN/GOST/CCC. Protection Marking: IP20.

IREM/IRET INVERTER 230: Entrance 230V I, exit 230V III
IREM/IRET INVERTER 400: Entrance 400V III, exit 400V III

EMC filter incorporated for models from 47A (included)

*Lineal load rated current

**Quadratic load rated current

Model
NRD-F400 (GENERIC)
Code
Information
ANTI-VIBRATION RUBBER BLOCK

MANUFACTURING FEATURES

• Support of great radial and axial elasticity.
• These low-profile, compact and elastic supports control the three directions of movement with large deformations in the rubber.
• It consists of two parallel armour adhered to the bell-shaped rubber and by a base with handles.
• These supports with handles have a threaded hole in their upper frame and are easy to install and fix.
• The steel protection washer allows it to withstand overloads by increasing its rigidity and protects the rubber from dripping hydrocarbons.
• Elastomer type NR or high quality elastomer. Working temperatures between -40ºC and + 70º C.
• Taking into account the tolerances of hardness in the elastomers, the mechanical characteristics of these series may differ.
• Range of 6 sizes and 3 different hardnesses (45-60-75) to fit a load range between 2 Kg and 1300 Kg.
      1. Soft: hardness A 45
      2. Average: hardness B 60
      3. Hard: hardness C 75

APPLICATIONS

• Very appropriate in the elastic suspensions of machines that present vibrations of horizontal components.

Model
XS-F400 (GENERIC)
Code
Information
ANTI-VIBRATION SPRING BLOCK

MANUFACTURING FEATURES

• Metal insulators designed to work with compression with 85% insulation according to the following arrows (travel in mm) and rpm:

Arrow (mm.)          r.p.m.
    20 mm          >600 r.p.m.
    30 mm          >500 r.p.m.

• Made of high quality elastic steel, with rectangular base and rubber mat to improve the grip. It treats of a resistant product and easy assembly, that avoids all type of vibrations of the fans to the structure of the premises.
• Operating temperature from -45 ° C to + 120 ° C.

APPLICATION

• To install under machines with rotating components, ventilation groups, fans, ventilation boxes, etc.