fan image
Model
VORTICENT CRC-A ATEX 56 T4 5,5kW Zone 2: FAN (Ex h IIB+H2 T4 Gc) + MOTOR (Ex db IIC T4 Gb)
Code

VORTICENT CRC-A ATEX 56 T4 5,5kW Zone 2: FAN (Ex h IIB+H2 T4 Gc) + MOTOR (Ex db IIC T4 Gb)

PLASTIC ATEX FAN WITH FORWARD IMPELLER

MANUFACTURING FEATURES

• Housing made of PP-el plastic (for models size 35 and equal to or greater than size 45) other models PE-el casing
• Forward curved impeller in PP plastic.
• Motor support made of rolled steel sheet with polyester powder finishing coat.
• Stainless steel nuts and bolts.
• Standard asynchronous squirrel-cage motor, IP-55, class F insulation. Standard voltages 230/400V 50Hz. Equipped with ATEX motors

• Available positions (to be indicated in case of order): LG270, LG0, LG45, LG90, LG135, LG180, LG225, LG315, RD0, RD45, RD90, RD135, RD180, RD225, RD270, RD315.
• The indicated codes correspond to the model in position LG270

APPLICATIONS
Designed for inline installation, they are suitable for:
• Corrosive air transport.
• Chemical and petrochemical industry.
• Laboratories and gas cabinets.
• General ventilation in closed environments classified as ATEX zone 2.
• Maximum temperature of transported air: If it is clean air 70ºC, other depends on the gas (see table in documentation)

UNDER REQUEST
• 60Hz fans and special voltages fans.
• Stainless steel motor support.

In compliance with the ATEX Directive 2014/34/UE. Certified ATEX II3G with certified ATEX motor for areas 2 (gas)

Fan

Max flow
8990 m³/h
Weight
120 Kg

Motor

Power
5,5 kW
RPM Motor
1455
I max. 400 V
11,5
Size
132S
Weight
42 Kg
Efficiency
85 %
FP
0.81
VORTICENT CRC-A ATEX 56 T4 5,5kW Zone 2: FAN (Ex h IIB+H2 T4 Gc) + MOTOR (Ex db IIC T4 Gb)
Loading...
Design point
Loading...
Service point
Loading...
Alternative point

VORTICENT CRC-A ATEX 56 T4 5,5kW Zone 2: FAN (Ex h IIB+H2 T4 Gc) + MOTOR (Ex db IIC T4 Gb)

Dimensions scheme
A B C D E F G H I L N Ø P R S T U V X X1 X2 Y Z
416 560 80 400 330 388 50 710 445 340 445 14 270 481 310 454 994 50 25 38 15 18 460

VORTICENT CRC-A ATEX 56 T4 5,5kW Zone 2: FAN (Ex h IIB+H2 T4 Gc) + MOTOR (Ex db IIC T4 Gb)

Electrical scheme

VORTICENT CRC-A ATEX 56 T4 5,5kW

Model
FLC1-F400 40
Code
21990
Information
ANTI-VIBRATING FLANGE 400º/2H

MANUFACTURING FEATURES

• Flexible polyurethane coupling flange with fiberglass fabric to avoid possible vibrations to the installation.
• 160 mm width and supplied with 2 fixing clamps.
• Certified according to the European standard EN 12101-3 400ºC/2h. Fire classification: M0.

Model
SWT-ATEX 25
Code
Information
ATEX SWITCH

Switch for ATEX environments. Suitable for zones 1-2 (gas) and 21-22 (dust), index protection IP65. Manufactured in aluminum alloy and RAL 7000 gray finishing coat. External screws in stainless steel. Control on the front. Tensions up to 690V. According to directive 2014/34 / UE (ATEX).

Model
IRET INVERTER 400 12A
Code
12881
Information
FREQUENCY SPEED CONTROLLER

Designed for controlling fan motors speed in HACV applications. Ultra compact installation, simple cabling, easy parameterization and wide standard functions. Integrated control unit panel with digital dial. PID card. Certifications: CE/UL/CSA/EN/GOST/CCC. Protection Marking: IP20.

IREM/IRET INVERTER 230: Entrance 230V I, exit 230V III
IREM/IRET INVERTER 400: Entrance 400V III, exit 400V III

EMC filter incorporated for models from 47A (included)

*Lineal load rated current

**Quadratic load rated current