MPC ED EVO F400
Model
MPC ED EVO 400 T2/T4 UN F400
Code

MPC ED EVO 400 T2/T4 UN F400

LONG CASE AXIAL FAN 400ºC/2H

MANUFACTURING FEATURES:

• Long case axial fan with reinforced body.
• Modular motor-impeller assembly. Cast aluminium impeller with variable pitch angle. Polyester powder finishing coat.
• Housing with motor access door for easy connection.
• Standard asynchronous squirrel-cage motor with IP-55 protection and Class H insulation certified 400ºC/2h. Manufactured with standard voltages:400V(Y) 50Hz) for 1 speed motors and 400V 50Hz for 2 speed motors.

APPLICATIONS:

Designed for inline installation, they are suitable for:
• Smoke emergency exhaust with motor inside the hazardous area.
• Maximum working temperature: 60ºC.

UNDER REQUEST:

• Supply impeller (air direction from impeller to motor).
• 100% reversible impeller.

Fan

Max flow
8060 m³/h
Weight
47 Kg

Motor

Power
1,1/0,18 kW
RPM Motor
2850/1450
I max. 400 V
2,36/0,59
Size
80
Weight
11.2 Kg
Efficiency
76/70 %
FP
0.84/0.76
MPC ED EVO 400 T2/T4 UN F400
Loading...
Design point
Loading...
Service point
Loading...
Alternative point

MPC ED EVO 400 T2/T4 UN F400

Dimensions scheme
A E J O ØB ØD
472 425 12 8x45º 450 401

MPC ED EVO 400 T2/T4 UN F400

Electrical scheme

MPC ED EVO 400 T2/T4 UN F400

Model
MFLAC 40/16
Code
20237
Information
CONECTION FLANGE

MANUFACTURING FEATURES

• For axial (inlet and outlet) and centrifugal (inlet) fans.

UNDER REQUEST

• Versions in stainless 304 and stainless 316.

Model
FLC1-F400 40
Code
21990
Information
ANTI-VIBRATING FLANGE 400º/2H

MANUFACTURING FEATURES

• Flexible polyurethane coupling flange with fiberglass fabric to avoid possible vibrations to the installation.
• 160 mm width and supplied with 2 fixing clamps.
• Fire classification: M0.

Model
SIL-C 400/400
Code
20807
Information
CIRCULAR SILENCER

MANUFACTURING FEATURES

• Valid for mounting in inlet and outlet according to the diameter of the corresponding pipe or adapted to the diameter of an optional flange. Consult to Casals Ventilación.
• Steel housing with thickness of 0.8mm for diameters up to 1250mm; and 1mm for higher diameters.
• Silencer flange with threaded inserts.
• Acoustic rock wool insulation of 70Kg/m3 with microperforated metal mesh that protects the fiberglass from erosion. Fire resistant insulation M0.
• Attenuation test carried out according to the ISO 7235 standard.
• Drills in accordance with Eurovent regulations.
• SIL-CN are equipped with an inner core that increases silencer attenuation.
• Maximum working temperature: 150ºC.
• Suitable for pressures up to 1000Pa

APPLICATIONS

• For attenuating the sound level of the fan.
• For coupling fans and circular pipes.

Other sizes, consult us.

Model
SIL-C 400/600
Code
20808
Information
CIRCULAR SILENCER

MANUFACTURING FEATURES

• Valid for mounting in inlet and outlet according to the diameter of the corresponding pipe or adapted to the diameter of an optional flange. Consult to Casals Ventilación.
• Steel housing with thickness of 0.8mm for diameters up to 1250mm; and 1mm for higher diameters.
• Silencer flange with threaded inserts.
• Acoustic rock wool insulation of 70Kg/m3 with microperforated metal mesh that protects the fiberglass from erosion. Fire resistant insulation M0.
• Attenuation test carried out according to the ISO 7235 standard.
• Drills in accordance with Eurovent regulations.
• SIL-CN are equipped with an inner core that increases silencer attenuation.
• Maximum working temperature: 150ºC.
• Suitable for pressures up to 1000Pa

APPLICATIONS

• For attenuating the sound level of the fan.
• For coupling fans and circular pipes.

Other sizes, consult us.

Model
SIL-C 400/800
Code
20809
Information
CIRCULAR SILENCER

MANUFACTURING FEATURES

• Valid for mounting in inlet and outlet according to the diameter of the corresponding pipe or adapted to the diameter of an optional flange. Consult to Casals Ventilación.
• Steel housing with thickness of 0.8mm for diameters up to 1250mm; and 1mm for higher diameters.
• Silencer flange with threaded inserts.
• Acoustic rock wool insulation of 70Kg/m3 with microperforated metal mesh that protects the fiberglass from erosion. Fire resistant insulation M0.
• Attenuation test carried out according to the ISO 7235 standard.
• Drills in accordance with Eurovent regulations.
• SIL-CN are equipped with an inner core that increases silencer attenuation.
• Maximum working temperature: 150ºC.
• Suitable for pressures up to 1000Pa

APPLICATIONS

• For attenuating the sound level of the fan.
• For coupling fans and circular pipes.

Other sizes, consult us.

Model
SIL-CN 400/400
Code
20786
Information
CIRCULAR SILENCER

MANUFACTURING FEATURES

• Valid for mounting in inlet and outlet according to the diameter of the corresponding pipe or adapted to the diameter of an optional flange. Consult to Casals Ventilación.
• Steel housing with thickness of 0.8mm for diameters up to 1250mm; and 1mm for higher diameters.
• Silencer flange with threaded inserts.
• Acoustic rock wool insulation of 70Kg/m3 with microperforated metal mesh that protects the fiberglass from erosion. Fire resistant insulation M0.
• Attenuation test carried out according to the ISO 7235 standard.
• Drills in accordance with Eurovent regulations.
• SIL-CN are equipped with an inner core that increases silencer attenuation.
• Maximum working temperature: 150ºC.
• Suitable for pressures up to 1000Pa

APPLICATIONS

• For attenuating the sound level of the fan.
• For coupling fans and circular pipes.

Other sizes, consult us.

Model
SIL-CN 400/600
Code
20787
Information
CIRCULAR SILENCER

MANUFACTURING FEATURES

• Valid for mounting in inlet and outlet according to the diameter of the corresponding pipe or adapted to the diameter of an optional flange. Consult to Casals Ventilación.
• Steel housing with thickness of 0.8mm for diameters up to 1250mm; and 1mm for higher diameters.
• Silencer flange with threaded inserts.
• Acoustic rock wool insulation of 70Kg/m3 with microperforated metal mesh that protects the fiberglass from erosion. Fire resistant insulation M0.
• Attenuation test carried out according to the ISO 7235 standard.
• Drills in accordance with Eurovent regulations.
• SIL-CN are equipped with an inner core that increases silencer attenuation.
• Maximum working temperature: 150ºC.
• Suitable for pressures up to 1000Pa

APPLICATIONS

• For attenuating the sound level of the fan.
• For coupling fans and circular pipes.

Other sizes, consult us.

Model
SIL-CN 400/800
Code
20788
Information
CIRCULAR SILENCER

MANUFACTURING FEATURES

• Valid for mounting in inlet and outlet according to the diameter of the corresponding pipe or adapted to the diameter of an optional flange. Consult to Casals Ventilación.
• Steel housing with thickness of 0.8mm for diameters up to 1250mm; and 1mm for higher diameters.
• Silencer flange with threaded inserts.
• Acoustic rock wool insulation of 70Kg/m3 with microperforated metal mesh that protects the fiberglass from erosion. Fire resistant insulation M0.
• Attenuation test carried out according to the ISO 7235 standard.
• Drills in accordance with Eurovent regulations.
• SIL-CN are equipped with an inner core that increases silencer attenuation.
• Maximum working temperature: 150ºC.
• Suitable for pressures up to 1000Pa

APPLICATIONS

• For attenuating the sound level of the fan.
• For coupling fans and circular pipes.

Other sizes, consult us.

Model
SWT F400 25 6P
Code
21692
Information
SAFETY SWITCH FOR 400ºC/2h

Safety switch for local disconnection of 400ºC/2h ventilation equipments according to UNE-EN 12101-3.
Suited for direct control of motor in AC 3 operation category
Equips two auxiliary contact.

Model
BAD 11
Code
20771
Information
CIRCULAR-CIRCULAR ANTI-VIBRATION FLANGE

MANUFACTURING FEATURES

• Circular-circular coupling flange through anti-vibration canvas.
• Fire resistance M0: from -50ºC to +200ºC in continuous and 400ºC/2h

Model
SWT 25 6P
Code
21680
Information
SAFETY SWITCH

MANUFACTURING FEATURES

• Safety start-stop switches according to IEC 60947-1 and IEC 60947-3.
• IP65 and always equipped an auxiliary contact.
• Useful for switching off the current before handling the fan.

*Máx. thermal current air (A)