fan image
Model
VORT JET-A 400 LP F300
Code
43544

VORT JET-A 400 LP F300

AXIAL JET FAN 300ºC/2h

MANUFACTURING FEATURES:

The JF models are composed of an axial fan and two silencers.

FAN:
• Axial fan with galvanized steel casing. The connection box is accessible by the side from a removable door.
• Standard asynchronous squirrel-cage motor with IP-55 protection and Class H insulation, CERTIFIED 300ºC/2h. Standard voltages 400V(Y) 50Hz for 1 speed motors and 400V 50Hz for 2 speed motors.

SILENCERS:
• Casing in galvanized steel. Inner duct made of perforated galvanized steel sheet. The silencers are filled with mineral wool with high acoustic absorption properties, preventing most of the fan noise to be propagated.
• Unidirectional VORT JET-A LP F300 UN is equipped with a protection guard at the inlet side and a deflector at the outlet. The deflector directs the air away from the ceiling and obstacles like beams or ducting, sweeping the whole volume of air to the closest extraction point.
• Reversible VORT JET-A LP F300 RE is equipped with protection guards on both sides.

APPLICATIONS:

• Conceived for car parkings and large spaces where polluted air, or smoke from an accidental fire, needs to be removed effectively. An optimized design minimizes the height needed for their installation and assures a silent operation.
• Maximum working temperature: 60ºC.

 

Fan

Max flow
8470 m³/h
Weight
70 Kg

Motor

Power
1,1 kW
RPM Motor
2860
I max. 400 V
2,39
Size
80
Weight
14 Kg
Efficiency
80.5 %
FP
0.85
VORT JET-A 400 LP F300
Loading...
Design point
Loading...
Service point
Loading...
Alternative point

VORT JET-A 400 LP F300

Dimensions scheme
A B C D E F G H I J L M ØK Thrust (N)
2415 758 440,5 1025 720 664 434 506 233 20 122 365 15 53

VORT JET-A 400 LP F300

Electrical scheme

VORT JET-A 400 LP F300

Model
SWT 25 3P
Code
21673
Information
SAFETY SWITCH

MANUFACTURING FEATURES

• Safety start-stop switches according to IEC 60947-1 and IEC 60947-3.
• IP65 and always equipped an auxiliary contact.
• Useful for switching off the current before handling the fan.

*Máx. thermal current air (A)

Model
SWT F400 25 3P
Code
21687
Information
SAFETY SWITCH FOR 400ºC/2h

Safety switch for local disconnection of 400ºC/2h ventilation equipments according to UNE-EN 12101-3.
Suited for direct control of motor in AC 3 operation category
Equips two auxiliary contact.

VORT JET-A 400 LP F300