ROOF FAN, AL COWL ATEX

MANUFACTURING FEATURES
• Roof cowl made of aluminium
• Structure, roof base support and bird protection guard made of galvanised steel.
• High efficiency backward impeller with self-cleaning system of steel.
• ATEX standard asynchronous motor. ATEX certified according to the zone. IP55 protection and class F insulation. Manufactured with standard voltages: 230/400V 50Hz in three phase motors up to 4kW and 400/690V 50Hz for higher powers.

APPLICATIONS
Ventilation in indoor environments classified as ATEX. Specially designed for roof installation, they are suitable for:
• Smoke extraction.
• Smoke emergency exhaust with motor outside the hazardous area.
• Air renewal in buildings and industries.
• Industrial and professional kitchen hoods.
• Working temperature: ambient from -20ºC to 40ºC, transported air according to the ATEX clasification.

UNDER REQUEST

• 60Hz and special voltages.

Fan

Max flow
2190 m³/h
Weight
15 Kg

Motor

Power
0,25 kW
RPM Motor
1400
I max. 230 V
1,93
Size
71
Weight
5.5 Kg
Efficiency
61 %
FP
0.92
TORRETTE TR-A 315 M4 0,25KW ATEX Zone 1: FAN (Ex h IIB+H2 T4 Gb) + MOTOR (Ex db IIC T5 Gb)
Loading...
Design point
Loading...
Service point
Loading...
Alternative point

TORRETTE TR-A 315 M4 0,25KW ATEX Zone 1: FAN (Ex h IIB+H2 T4 Gb) + MOTOR (Ex db IIC T5 Gb)

Dimensions scheme
A B aprox C D E F G H I K aprox
583 544,6 595 450 9 203 185,25 40 20,75 298,5

TORRETTE TR-A 315 M4 0,25KW ATEX Zone 1: FAN (Ex h IIB+H2 T4 Gb) + MOTOR (Ex db IIC T5 Gb)

Electrical scheme

TORRETTE TR-A 315 M4 0,25KW ATEX

Model
SWT 25 3P
Code
21673
Information
SAFETY SWITCH

MANUFACTURING FEATURES

• Safety start-stop switches according to IEC 60947-1 and IEC 60947-3.
• IP65 and always equipped an auxiliary contact.
• Useful for switching off the current before handling the fan.

*Máx. thermal current air (A)

Model
INT 16 ATEX
Code
20355
Information
ATEX SWITCH

Switch for ATEX environments. Suitable for zones 1-2 (gas) and 21-22 (dust), index protection IP65. Manufactured in aluminum alloy and RAL 7000 gray finishing coat. External screws in stainless steel. Control on the front. Tensions up to 690V. According to directive 2014/34 / UE (ATEX).

Model
BTI 570 D=0 C=B
Code
20761
Information
INCLINED ROOF FAN SUPPORT

MANUFACTURING FEATURES

• Inclined support for roof fans , TORRETTE TRS EC, TORRETTE TRK R, and the resulting fans combining with the KIT TE and KIT TM

In the code, indicate the pitch instead of "XX"

UNDER REQUEST

• Specific inclination.

TORRETTE TR-A 315 M4 0,25KW ATEX Zone 1: FAN (Ex h IIB+H2 T4 Gb) + MOTOR (Ex db IIC T5 Gb)