VORTICENT CMS NMU ATEX
Model
VORTICENT CMS-NMU 801 T6 4kW ATEX Zone 2: FAN (Ex h IIB T3 Gc) + MOTOR (Ex ec IIC T3 Gc)
Code

VORTICENT CMS-NMU 801 T6 4kW ATEX Zone 2: FAN (Ex h IIB T3 Gc) + MOTOR (Ex ec IIC T3 Gc)

CENTRIFUGAL FAN WITH BACKWARD IMPELLER, DIRECT DRIVEN WITH FEET MOTOR (B3) ATEX.

MANUFACTURING FEATURES

• Medium pressure centrifugal fan with direct coupling.
• Reinforced housing made of carbon laminated steel, protected against corrosion by powder coating polyester resin RAL 5010. Finish C3.
• Self-cleaning impeller and reinforced impeller with high-performance backward (reaction) blades made of carbon laminated steel dynamically balanced to minimize noise and vibrations. Black painted RAL 9005
• ATEX standard asynchronous motor. ATEX certified according to the zone. Class F insulation. Manufactured with standard voltages: 230/400V 50Hz for three phase motors up to 4kW and 400/690V 50Hz for higher powers.
• Motor with feet (B3) supported on motor support foot.
• Models of size 500 and above are supplied with a front support foot, for the other models the front support foot is optional.
• Working temperature: ambient from -20ºC to 40ºC, transported air according to the ATEX clasification.

• Available positions (to be indicated in case of order): LG270, LG0, LG45, LG90, LG135, LG180, LG225, LG315, RD0, RD45, RD90, RD135, RD180, RD225, RD270, RD315.
• The indicated codes correspond to the model in position LG270

APPLICATIONS

• Ventilation in indoor environments classified as ATEX. Suitable for moving clean or dusty air. Designed to be installed in conduit for suction or impulsion.

  •      Paint booths
  •      Collection of dust
  •      Food industry dryers
  •      Food processing
  •      Incineration
  •      Odor control in industry
  •      Indoor / outdoor pollution control
  •      Big buildings
  •      Malls
  •      Factories / Industrial buildings
  •      Warehouses
  •      Extraction of smoke
  •      Boilers and ovens
  •      Manufacture and treatment of chemical products.
  •      Tunnels, underground stations.

ON DEMAND


· Fans for 60Hz and special voltages.
· Inox 304 (normal or electropolished finish)
· Inox 316 (normal or electropolished finish)
· Inspection door to facilitate maintenance and cleaning
· Drain plug.

Fan

Max flow
25740 m³/h

Motor

Power
4 kW
RPM Motor
960
I max. 230 V
16,5
I max. 400 V
9,46
Size
132M
Weight
68 Kg
Efficiency
84 %
FP
0.74
VORTICENT CMS-NMU 801 T6 4kW ATEX Zone 2: FAN (Ex h IIB T3 Gc) + MOTOR (Ex ec IIC T3 Gc)
Loading...
Design point
Loading...
Service point
Loading...
Alternative point

VORTICENT CMS-NMU 801 T6 4kW ATEX Zone 2: FAN (Ex h IIB T3 Gc) + MOTOR (Ex ec IIC T3 Gc)

Dimensions scheme
A1 A2 B1 B2 C1 C2 C3 C4 C5 D D1 D2 E F (±) G (±) H HC I J K L M N N1 N2 O P Q R R1 R2 S T U V Y Z
945.7 645.3 543.6 781 577.5 1053.1 848.9 713.2 88.1 845 11.5 20 1125.6 1007.6 514 58.5 965 616 673.6 649.1 380 202.5 585 505 555 233 234 490.6 880 800 850 600 680 243.6 203.6 M8 16x22,5º

VORTICENT CMS-NMU 801 T6 4kW ATEX Zone 2: FAN (Ex h IIB T3 Gc) + MOTOR (Ex ec IIC T3 Gc)

Electrical scheme

VORTICENT CMS-NMU 801 T6 4kW ATEX

Model
MFL-F400 800
Code
21702
Information
CONECTION FLANGE

MANUFACTURING FEATURES

• For axial (inlet and outlet) and centrifugal (inlet) fans.

UNDER REQUEST

• Versions in stainless 304 and stainless 316.

Model
FLC1-F400 80
Code
21996
Information
ANTI-VIBRATING FLANGE 400º/2H

MANUFACTURING FEATURES

• Flexible polyurethane coupling flange with fiberglass fabric to avoid possible vibrations to the installation.
• 160 mm width and supplied with 2 fixing clamps.
• Fire classification: M0.

Model
FJ-F450
Code
21669
Information
ANTI-VIBRATION JOINT

MANUFACTURING FEATURES

• Flexible joint to clinch the fan to the duct.
• Avoids transmission of vibrations for circular and rectangular connection.
• Dimensions: two metallic flanges of 45mm each one and a flexible flange of 60mm.
• The reel is 30,5m lenght.
• Maximum pressure: 20 mmca.
• Fire resistance M0 from -50ºC to +200ºC in continuous and 400ºC/2h.

Model
IRET INVERTER 400 12A
Code
12881
Information
FREQUENCY SPEED CONTROLLER

Designed for controlling fan motors speed in HACV applications. Ultra compact installation, simple cabling, easy parameterization and wide standard functions. Integrated control unit panel with digital dial. PID card. Certifications: CE/UL/CSA/EN/GOST/CCC. Protection Marking: IP20.

IREM/IRET INVERTER 230: Entrance 230V I, exit 230V III
IREM/IRET INVERTER 400: Entrance 400V III, exit 400V III

EMC filter incorporated for models from 47A (included)

*Lineal load rated current

**Quadratic load rated current

Model
NRD-F400 (GENERIC)
Code
Information
ANTI-VIBRATION RUBBER BLOCK

MANUFACTURING FEATURES

• Support of great radial and axial elasticity.
• These low-profile, compact and elastic supports control the three directions of movement with large deformations in the rubber.
• It consists of two parallel armour adhered to the bell-shaped rubber and by a base with handles.
• These supports with handles have a threaded hole in their upper frame and are easy to install and fix.
• The steel protection washer allows it to withstand overloads by increasing its rigidity and protects the rubber from dripping hydrocarbons.
• Elastomer type NR or high quality elastomer. Working temperatures between -40ºC and + 70º C.
• Taking into account the tolerances of hardness in the elastomers, the mechanical characteristics of these series may differ.
• Range of 6 sizes and 3 different hardnesses (45-60-75) to fit a load range between 2 Kg and 1300 Kg.
      1. Soft: hardness A 45
      2. Average: hardness B 60
      3. Hard: hardness C 75

APPLICATIONS

• Very appropriate in the elastic suspensions of machines that present vibrations of horizontal components.

Model
XS-F400 (GENERIC)
Code
Information
ANTI-VIBRATION SPRING BLOCK

MANUFACTURING FEATURES

• Metal insulators designed to work with compression with 85% insulation according to the following arrows (travel in mm) and rpm:

Arrow (mm.)          r.p.m.
    20 mm          >600 r.p.m.
    30 mm          >500 r.p.m.

• Made of high quality elastic steel, with rectangular base and rubber mat to improve the grip. It treats of a resistant product and easy assembly, that avoids all type of vibrations of the fans to the structure of the premises.
• Operating temperature from -45 ° C to + 120 ° C.

APPLICATION

• To install under machines with rotating components, ventilation groups, fans, ventilation boxes, etc.